2012 Catalog

HF5 Humidity Temperature Transmitter

Hover over image to zoom*hover to zoom
HF5 Logo

The HF5 transmitter is designed for fixed installation in HVAC and industrial applications, and provides two analog outputs or a digital output signal corresponding to relative humidity, temperature, dew point or another psychrometric parameter. The HF5 uses a plug-in HygroClip 2 probe, the model of probe being determined by the application. The measuring range is within 0 to 100 %RH and -100 to 200°C (-148 to 392°F), depending on the probe. All HygroClip 2 probes feature durable sensors, consistent performance and can be hot-swapped at any time to facilitate routine calibrations.

The HF5 transmitter is available in different configurations and has an extensive set of settings and functions that can be configured and enabled with the ROTRONIC HW4 software after connecting the HF5 to a PC.

useful links

Airchip 3000 Logo

General specifications

  • Interchangeable probe facilitates maintenance and reduces service downtime
  • Large choice of probe models to meet the requirements of most applications
  • Measures relative humidity and temperature
  • Calculates dew point, frost point, wet-bulb temperature, mixing ratio, etc.
  • 0 to 100 %RH and -100 to 200 °C (-148 to 392 °F) - depending on probe model
  • Accuracy at 23 °C: ± 0.8 %RH and 0.1 °C

Output signal & display options

  • Optional LC display and keypad
  • Analog signals only / Analog signals and Digital interface / Digital interface only
  • Digital interface for the simultaneous reading of relative humidity, temperature and calculated parameter

Mechanical configuration options

  • Duct / through-wall.
  • Wall mount
  • Up to 5 m / 16.4 ft probe extension cable (100 m / 330 ft with a signal booster)

Electrical configuration options

  • 2-wire, loop-powered and 3-wire models
  • Supply voltage 2-wire models: 10 to 28 VDC
  • Supply voltage 3-wire models: 15 to 40 VDC / 12 to 28 VAC or 85 to 240 VAC

Other features

  • Configurable analog output signals (signal type, parameter and range)
  • Automatic RH sensor test with optional sensor drift correction 1)
  • Configurable fail safe mode - fixed output signals in the event of a humidity or temperature sensor failure
  • Simulator function (fixed output signals) for on-site validation of the measurement loop
  • Full access to the settings and functions via external service connector or via optional digital interface

Product of the Month

Product of the Month

Upcoming Events