MPH Series Humidity Temperature Meteorological Probe
Technical data MP100H (voltage outputs)
MP400H (current outputs)
Configurations
- Separate temperature probe with active linear output signal (standard)
- Separate temperature probe with direct 2-, 3- or 4-wire RTD connection (optional)
- No separate temperature probe - temperature output provided by RTD from HygroClip (optional)
Humidity Temperature Plug-in Probe HygroClip S3 (included with MPH) Humidity sensor: ROTRONIC Hygromer® C94 (capacitive) Temperature sensor: RTD Pt100 Ohm, 1/3 DIN
Sensor protection: Wire mesh filter (standard)
Foam filter (optional)Separate Temperature Probe Stainless steel rod 118 x 3 mm (4.64 x 0.12") Pt100 1/3 DIN RTD (standard)
Pt100 1/5 DIN RTD (optional)
Pt100 1/10 DIN RTD (optional)Operating/Measuring range 0...100%RH
-40...60°C / -40...140°FAccuracy at 23°C / 73°F <±1.5%RH and ±0.2°C (valid for active outputs) Repeatability better than 0.5%RH and 0.1°C Measuring ranges
(active outputs)0...1V = 0...100%RH 4...20mA = 0...100%RH 0...1V = -40...60°C (standard)
0...1V = -30...70°C (optional)
-0.4...0.6V = -40...60°C (optional)4...20mA = -40...60°C (standard)
4...20mA = -30...70°C (optional)Active Outputs Load > 1000 Ohm < 500 Ohm Supply Voltage 3.6...35VDC, 10 mA 5VDC + 0.02 x load, 45 mA max.
15VDC maximumCable Length Compensation effective for up to 100m/300ft N/A (current outputs) Connecting Cable standard: 3m (9ft) PUR cable with tinned ends Weight 210 g / 0.47 lb